Preparation and Characterization of Nanocrystalline Gadolinium Oxide Powders and Films
2020
Due to its magnetic, electrical, absorption, and emission properties, nanoscale gadolinium oxide is widely used in various fields. In this research, nanocrystalline Gd2O3 powders and films on glass substrates have been produced by the extraction-pyrolytic method. X-ray diffraction analysis revealed the formation of single phase Gd2O3 with cubic crystal structure and the mean crystallite size from 9 to 25 nm in all produced materials. The morphology of samples has been characterized by scanning electron microscopy and transmission electron microscopy.
Fluorimetric determination of amphetamine in urine by flow injection with on-line liquid–liquid extraction
2001
Abstract Determination of amphetamine in urine was performed by batch and flow injection methodologies. The suitable experimental conditions for fluorimetric measurements were established. The liquid–liquid extraction was carried out at pH 13 using diethyl ether as extracting reagent. The measurement conditions were 260 nm and 277 nm for excitation and emission wavelengths, respectively. The method requires standard addition calibration and Youden blank correction. The influence of the main metabolites of amphetamine and metamphetamine were studied. The accuracy and precision of the proposed method was tested and the method is adapted to the flow injection procedure with on-line extraction.
Potential of phosphonium-based ionic liquids to purify 1-propanol from water by liquid–liquid extraction at mild conditions
2022
Abstract In order to reduce the environmental of the separation of 1-propanol from water in a residual industry stream for its reuse, the capability as solvents of two different trihexyl(tetradecyl)phosphonium ionic liquids (ILs) – trihexyl(tetradecyl)phosphonium chloride ([TDTHP][Cl]) and trihexyl(tetradecyl)phosphonium bromide ([TDTHP][Br])-, was studied. The liquid–liquid equilibria data for both ternary systems, {water + 1-propanol + [TDTHP][Cl]} and {water + 1-propanol + [TDTHP][Br]} at different mild work temperatures, (283.2, 303.2 and 323.2) K, and atmospheric pressure were measured. The thermodynamic parameters for both ternary systems at different work conditions were obtained by …
Development of a novel methodology for determination of dialkyl phosphates in human urine using liquid chromatography-tandem mass spectrometry
2019
Abstract In this study a fast and sensitive method was developed for the quantitative determination of six dialkyl phosphates (DAPs) in human urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The proposed methodology was based on liquid-liquid extraction (LLE) with diethyl ether and ethyl acetate using MgSO4 and NaCl, followed by liquid chromatography and mass spectrometry detection in the selected reaction mode (SRM) with negative electrospray ionization (ESI-). Detection settings were optimized by design of experiments (DoE). Dibutyl phosphate (DBP) was used as internal standard. Several criteria established in the SANTE/11813/2017 guidance document for pesticide resi…
Analysis of ecstasy in oral fluid by ion mobility spectrometry and infrared spectroscopy after liquid-liquid extraction.
2014
We developed and evaluated two different strategies for determining abuse drugs based on (i) the analysis of saliva by ion mobility spectrometry (IMS) after thermal desorption and (ii) the joint use of IMS and infrared (IR) spectroscopy after liquid-liquid microextraction (LLME) to enable the sensitivity-enhanced detection and double confirmation of ecstasy (MDMA) abuse. Both strategies proved effective for the intended purpose. Analysing saliva by IMS after thermal desorption, which provides a limit of detection (LOD) of 160μgL(-1), requires adding 0.2M acetic acid to the sample and using the truncated negative second derivative of the ion mobility spectrum. The joint use of IMS and IR spe…
MYCOTOXINS | Detection and Analysis by Classical Techniques
2014
This article is a revision of the previous edition article by Imad Ali Ahmed, volume 2, pp. 1526–1532, © 1999, Elsevier Ltd.
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid…
2002
A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte pe…
Development of a Rapid Method for the Determination of Phenolic Antioxidants in Dark Chocolate Using Ultra Performance Liquid Chromatography Coupled …
2017
Development of a new comprehensive method based on one-step liquid-liquid extraction (LLE) combined with ultra-high-performance liquid chromatography-Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-HRMS) for the determination of eight phenolic compounds in dark chocolate is demonstrated. The study focuses on the optimization of sample preparation, chromatographic separation and Orbitrap-HRMS detection parameters to adjust selectivity and sensitivity of the method. The LLE mixture of formic acid-water-acetonitrile (2:58:40, v/v) and hexane at the component ratio of 1:1 (v/v) was applied for sample preparation. The inter-day and intra-day precision expressed from the relative stand…
Development of new centrifuges for fast solvent extraction of transactinide elements
1995
The H-0.3 liquid-liquid centrifuge applied for rapid and efficient separation of two liquid phases, and the HG-0.1 gas-liquid centrifuge used to separate the gas phase stemming from a gas jet transportation system and the liquid phase, have been further improved. New centrifuges have been produced of PEEK, a plastic material, which makes them resistant to most aqueous and organic solutions. The performance with respect to time behavior and phase purity is comparable to the titanium centrifuges used so far. The H-0.3 centrifuge has been applied to solvent extraction studies of Zr, Nb, Mo, Hf, Ta, W and Pa from HF solutions into tri-n-octylamine.